Skip to content
We independently pick everything we recommend. We earn a commission when you buy through our links, at no extra cost to you. Learn more ›
Amazon Black Friday Week deals

Shielding Gas Cylinder Run Time Calculator

A shielding gas cylinder holds a fixed volume of gas, and the flowmeter lets it out at a steady rate. Divide one by the other and you have the hours of arc time left in the tank. Enter the cylinder size, how full it is and your flow rate to see the run time.

Cylinder run time

Argon and mixed gas cylinders are sold by cubic feet. CO2 is sold by the pound.
The size stamped on the cylinder or printed on the fill receipt.
100 for a fresh fill. Use 50 if the tank gauge reads about half.
What your flowmeter or regulator is set to while welding.
Trigger time only, not hours in the shop.
4 hours of arc time

    Run time counts gas flowing at the set rate. Pre-flow, post-flow and leaks at fittings use gas too, so real run time is a little shorter.

    How the calculation works

    1. Gas in the cylinder. Argon and argon/CO2 mixes are sold by volume, so an 80 cu ft cylinder holds 80 cubic feet of gas when full. Multiply by how full the cylinder is.
    2. CO2 by the pound. CO2 is stored as a liquid and sold by weight. One pound of liquid CO2 becomes about 8.74 cubic feet of gas at 70°F and normal air pressure, so a 20 lb cylinder holds about 175 cubic feet.
    3. Run time. Hours of arc time = cubic feet of gas ÷ flow rate in cubic feet per hour (CFH). If your flowmeter reads liters per minute, 1 CFH is 0.4719 L/min.

    Example: an 80 cu ft cylinder at 20 CFH gives 80 ÷ 20 = 4 hours of arc time. At 15 minutes of trigger time a day, that is 16 days.

    Reading the result

    • Arc time is not shop time. Gas only flows while the trigger or pedal is down, plus pre-flow and post-flow. An hour in the shop is often only a few minutes of arc time.
    • The tank gauge on argon shows pressure. Pressure in an argon or mixed gas cylinder falls roughly in step with the gas used, so a half reading means about half the gas is left.
    • The tank gauge on CO2 does not. A CO2 cylinder holds pressure while liquid remains, then drops quickly. Weighing the cylinder and subtracting the stamped empty (tare) weight is the reliable way to see what is left.
    • Leaks shorten everything. A hissing fitting or a cracked hose can empty a cylinder between sessions. Close the cylinder valve when you finish.

    Cylinders are high-pressure vessels. Keep them chained upright with the cap on when they are not in use, and see our safety disclaimer.